CONTAINTER CORP OF AMERICA -- PYROCIDE -- 8010-00N017681
=====================  Product Identification  =====================

Product ID:PYROCIDE
MSDS Date:01/25/1989
FSC:8010
NIIN:00N017681
=== Responsible Party ===
Company Name:CONTAINTER CORP OF AMERICA
Address:850 LUNT AVE
City:ELK GROVE VILLAGE
State:IL
ZIP:60007
Country:US
Info Phone Num:312-228-9404
Emergency Phone Num:312-228-9404
CAGE:86255
=== Contractor Identification ===
Company Name:CONTAINTER CORP OF AMERICA
Address:850 LUNT AVE
Box:City:ELK GROVE VILLAGE
State:IL
ZIP:60007
Country:US
Phone:312-228-9404
CAGE:86255

=============  Composition/Information on Ingredients  =============

Ingred Name:ETHYLENE, CHLORO-, POLYMER; (POLYVINYLIDENE CHLORIDE)
CAS:9002-86-2
RTECS #:KV0350000
Fraction by Wt: 0.2%

Ingred Name:PHOSPHATES

Ingred Name:POLYOLS

Ingred Name:VENT: PROVES INADEQUATE TO MAINTAIN SAFE VAP CONC,
    SUPPLEMENTAL LOCAL EXHAUST MAY BE REQD.OTHER SPECIAL PREC,(SEE ING
    5)
RTECS #:9999999ZZ

Ingred Name:INGRED 4: SUCH AS RESP PROT, MAY BE REQD IF VAP CONC CANNOT
    BE REDUCED TO BELOW TLV BY VENT.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:EYE: PRODUCT MAY BE AN EYE IRRITANT.
    SKIN: PROD MAY CAUSE SKIN IRRITATION UPON PROLONGED OR REPEATED
    CONTACT. SYSTEM EFFECTS: NORMAL UTILIZATION OF PRODUCT SHOULD NOT
    GENERATE RESIDUAL MONOMER CONCENT RATION IN EXCESS OF RECOGNIZED
    TLV. HOWEVER, SHOULD EXPOSURE TO CONCENTRATION GREATER THAN TLV
    (SEE EFTS OF OVEREXPOS)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: BE ENCOUNTERED, REACTIONS SIMILAR TO
    THOSE EXPECTED FROM PURE MONOMER MAY RESULT. ANY TOXICITY RELATED
    TO THIS PRODUCT IS NOT DUE TO THE RELATIVELY INERT, NON-TOXIC
    POLYMER, BUT RATHER TO TH E RESIDUAL MONOMER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EYE: HOLDING LIDS APART, FLUSH CONTAMD EYE(S) W/GENTLE STREAM
    OF WATER FOR AT LEAST 15 MIN. IF IRRIT/REDNESS DEVELOP & PERSIST,
    SEEK IMMED MED ATTN. SKIN: REMOVE CONTAM CLTHG & CLEANSE SKIN THORO
    W/SO AP & H*2O. SEEK MED ATTN IF IRRIT, SWELLING, BLISTERING OR
    REDNESS DEVELOP & PERSIST. INHAL: NO FIRST AID IS NORMALLY REQD.
    HOWEVER, SEEK MED ADVISE IF ANY UNUSUAL SYMP DEVELOP. INGEST:(SEE
    SUPP DATA)

=====================  Fire Fighting Measures  =====================

Flash Point:NONE TO BOILING
Extinguishing Media:DRIED SOLIDS:USE H*2O, FOAM,CO*2/DRY CHEM FIRE
    FIGHTING APPARATUS.H*2O MAY BE HELPFUL IN KEEPING FIRE EXPOS CNTNRS
    COOL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS EXPOSED TO EXTREME HEAT
    MAY RUPTURE DUE TO PRESSURE BUILDUP.

==================  Accidental Release Measures  ==================

Spill Release Procedures:FLUSH SPILLED MATL INTO SUITABLE RETAINING
    AREAS/CNTNRS W/LRG QTYS OF H*2O.SMALL AMTS OF SPILLED MATL MAY BE
    ABSORB INTO APPROP ABSORB.PVNT SPILLED LIQ FROM ENTERING SEWERS,
    STORM DRAINS, OTHER UNAUTH ORIZED TREATMENT/DRAINAGE SYS &
    NATURALWATERWAYS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP PROD CNTNRS COOL, DRY, & AWAY
    FROM SOURCES OF IGNIT. USE & STORE PROD W/ADEQ VENT. KEEP PROD
    CNTNRS CLSD WHEN NOT IN USE.
Other Precautions:AVOID SUBJECTING PROD TO EXTREME TEMP VARIATIONS &
    FREEZING. SHOCKING EMULSION W/LRG QTYS OF CHEMS/EXTREME SHEAR MAY
    CAUSE COAGULATION. IN GEN, MINIMAL HLTH & SFTY HAZ ARE EXPECTED
    FROM USE OF PROD. W HEN WORKING W/CHEM (SEE SUPP DATA)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE OF RESP PROT DEPENDS ON VAP CONC ABOVE
    TIME-WEIGHTED TLV. USE NIOSH/MSHA APPROVED RESP/GAS MASK WITH
    APPROPRIATE CARTRIDGES & CANISTER, OR SUP AIR EQUIP, DEPENDING ON
    AIRBORNE CONCENTRATION.
Ventilation:GEN MECH VENT MAY BE SUFFICIENT TO KEEP PROD VAP CONC W/IN
    SPECIFIED TIME-WEIGHTED TLV RANGES. IF GEN VENT (SEE ING 4)
Protective Gloves:IMPERMEABLE GLOVES.
Eye Protection:CHEM WORK GOG & FULL LGTH FACESHLD
Other Protective Equipment:PROT CLOTHING IS ADVISED AS GOOD CHEM HNDLG
    PRACTICE. AVAILABILITY OF EYE WASHES & SFTY SHOWERS IN WORK AREAS
    IS RECOM.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
VAP DENS: LIGHTER THAN AIR. FIRST AID PROC: DRINK 2 OR 3 CUPS OF MILK,
    FRUIT JUICE/H*2O. NO OTHER FIRST AID IS NORMALLY REQD. HOWEVER, IF
    ANY UNUSUAL SYMP DEVELOP, SEEK MED ADVICE. OTHER PREC: COMPOUN D,
    PRUDENT HNDLG PRACTICES SHOULD BE EXERCISED & UNNEC EXPOS AVOIDED.
    LAUNDER SATURATED CLOTHING BEFORE WEARING.

==================  Physical/Chemical Properties  ==================

HCC:N1
Boiling Pt:B.P. Text:212F,100C
Vapor Density:SUPP DATA
Spec Gravity:HVR THAN H*2O
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:INSOLUBLE
Appearance and Odor:MILKY WHITE WITH FAINT ODOR.
Percent Volatiles by Volume:50

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NO HAZ RXNS EXPECTED TO OCCUR UNDER NORMAL TRIAL
    CONDITIONS;HOWEVER,PROD PROPERTIES MAY BE ALTERED BY MIXG W/SOME
    MATLS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:THERMAL DECOMP IN PRESENCE OF AIR MAY
    YIELD CO AND/OR C*2 AND TRACES OF MONOMER AND HYDROCHLORIC ACID.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF PRODUCT IN ACCORDANCE WITH APPLICABLE
    LOCAL, COUNTY, STATE, AND FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.