WITCO CHEMICAL CORP -- PETROLEUM HYDROCARBON PLUS ADDITIVE SE 861 0632 -- 9150-00F022243
=====================  Product Identification  =====================

Product ID:PETROLEUM HYDROCARBON PLUS ADDITIVE SE 861 0632
MSDS Date:08/29/1988
FSC:9150
NIIN:00F022243
=== Responsible Party ===
Company Name:WITCO CHEMICAL CORP
Address:1400 S HARRISON
Box:1974
City:OLATHE
State:KS
ZIP:66061
Country:US
Info Phone Num:913 782-5800
Emergency Phone Num:913 782-5800
Preparer's Name:RAY D LAWSON
CAGE:1F469
=== Contractor Identification ===
Company Name:EXXON CO USA-SOUTHWEST GREASE BUSINESS UNIT
Address:1400 S HARRISON
Box:1974
City:OLATHE
State:KS
ZIP:66061
Country:US
Phone:913-656-3701/800-424-9300(CHEMTREC)
CAGE:70878
Company Name:WITCO CHEMICAL CORP GOLDEN BEAR OIL CO DIVISION
Address:MANOR & NORRIS ROADS
Box:5446
City:OILDALE
State:CA
ZIP:93388-5446
Country:US
Phone:805-393-7110/800-424-9300(CHEMTREC)
CAGE:1F469

=============  Composition/Information on Ingredients  =============

Ingred Name:PETROLEUM HYDROCARBON PLUS ADDITIVES

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:NO	Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:SKIN/EYE: IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:SKIN/EYE: IRRITATION.

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH W/LARGE QUANTITIES OF WATER FOR AT LEAST 15 MINS.
    SKIN: REMOVE EXCESS W/CLOTH OR PAPER. INHALATION: REMOVE EXPOSED
    PERSON TO FRESH AIR IF DISCOMFORT IS EXPERIENCED WHILE HANDLING HOT
    PRODU CT. INGESTION: OBTAIN MEDICAL ATTENTIONIN ALL CASES.

=====================  Fire Fighting Measures  =====================

Flash Point Method:COC
Flash Point:>302F
Extinguishing Media:DRY CHEMICAL, WATERFOG, CO2, FOAM OR SAND/EARTH
Fire Fighting Procedures:USE WATER TO KEEP FIRE-EXPOSED CONTAINERS
    COOL. DENSE SMOKE. WEAR AN APPROVED SELF-CONTAINED BREATHING
    APPARATUS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:TRANSFER BULK OF MIXTURE INTO ANOTHER
    CONTAINER. ABSORB RESIDUE W/AN INERT MATERIAL SUCH AS EARTH, SAND,
    OR VERMICULITE. SWEEP UP & DISPOSE AS SOLID WASTE.

======================	Handling and Storage  ======================

Handling and Storage Precautions:NONE WHEN USED W/GOOD PERSONAL HYGIENE
    PRACTICES. KEEP CONTAINER CLOSED UNTIL READY FOR USE. KEEP OUT OF
    REACH OF CHILDREN.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE
Ventilation:NONE
Protective Gloves:NONE
Eye Protection:CHEMICAL SAFETY GOGGLES & FACE SHIELD
Other Protective Equipment:NONE
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMBER, MINERAL OIL ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS, HYDROGEN PEROXIDE, BROMINE, & CHROMIC ACID
Hazardous Decomposition Products:CO, CO2, OXIDES OF NITROGEN

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE, &
    FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.