KANO LABORATORIES, INC -- KROIL -- 9150-00-985-7121
=====================  Product Identification  =====================

Product ID:KROIL
MSDS Date:01/01/1987
FSC:9150
NIIN:00-985-7121
=== Responsible Party ===
Company Name:KANO LABORATORIES, INC
Address:1000 THOMPSON LANE
City:NASHVILLE
State:TN
ZIP:37211-2627
Country:US
Preparer's Name:PR ZIMMERMAN
CAGE:13868
=== Contractor Identification ===
Company Name:KANO LABORATORIES, INC.
Address:1000 S. THOMPSON LANE
Box:City:NASHVILLE
State:TN
ZIP:37211-2627
Country:US
Phone:615-833-4101
CAGE:13868

=============  Composition/Information on Ingredients  =============

Ingred Name:CHEMICALLY NEUTRALIZED NAPTHENIC DISTILLATE.
CAS:64742-46-7
RTECS #:JN9379645
Fraction by Wt: V40%
Other REC Limits:
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:SEC-BUTYL ALCOHOL  (SARA III)
CAS:78-92-2
RTECS #:EO1750000
Fraction by Wt: V<3%
Other REC Limits:N/K 
OSHA PEL:150 PPM
ACGIH TLV:100 PPM; 9293

Ingred Name:SEC-BUTYL ALCOHOL  (SARA III)
CAS:78-92-2
RTECS #:EO1750000
Fraction by Wt: <3% V
Other REC Limits:N/K 
OSHA PEL:150 PPM
ACGIH TLV:100 PPM; 9293

Ingred Name:PALE OIL, PETROLEUM OIL OF MOTOR OIL VISCOSITY, MAKES UP
    BALANCE OF PROD
ACGIH TLV:5MG/CUM, MFG

Ingred Name:DICHLORODIFLUOROMETHANE  (SARA III)
CAS:75-71-8
RTECS #:PA8200000
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM; 9192
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ozone Depleting Chemical:1

=====================  Hazards Identification  =====================

Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Explanation of Carcinogenicity:N/A FPN
Effects of Overexposure:SLIGHT EYE IRRITATION,DRYING OF SKIN.EXCESSIVE
    INHALATION MAY CAUSE DIZZINESS OR NAUSEA.

=======================  First Aid Measures  =======================

First Aid:EYE:FLUSH W/ LG AMTS OF H*2O FOR 15 MIN.SKIN:WASH W/ MILD
    SOAP & H*2O,APPLY SKIN CREAM,INHAL:REMOVE TO FRESH AIR & APPLY
    ARTIFICIAL RESPIRATION IF NECESSARY.INGESTION: DO NOT INDUCE
    VOMITING,CALL PHYS ICIAN.

=====================  Fire Fighting Measures  =====================

Flash Point Method:COC
Flash Point:130F-54.44C
Extinguishing Media:CO*2,DRY CHEMICAL,FOAM
Fire Fighting Procedures:USUAL PROCEDURE FOR SOLVENTS,TREAT AS
    COMBUSTIBLE.
Unusual Fire/Explosion Hazard:IN FIRE SITUATION OR WHEN HEATED, THIS
    MTL IS HIGHLY FLAMMABLE

==================  Accidental Release Measures  ==================

Spill Release Procedures:WIPE UP IMMEDIATELY W/ ABSORB RAGS,SWEEPING
    COMPOUND OR OTHER ABSORB MAT.REMOVE OR EXTINGUISH ALL FLAMES &
    SPARKS.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP AWAY FROM EXCESSIVE HEAT,SPARKS &
    OPEN FLAME.DO NOT TAKE INTERNALLY.DO NOT LV CONTNR OPEN.STORE IN
    COOL AREA.
Other Precautions:USE WITH PROPER VENT.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF SPRAYED, NIOSH/MSHA APPRVD RESP PROT MAY BE
    NECESSARY
Ventilation:NORMAL LOCAL EXHAUST SYSTEM.MECHANICAL,NORMAL VENT IS
    SUFFICIENT.
Protective Gloves:CHEMICALLY RESISTANT GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE NEEDED (MFR).
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

HCC:F4
Boiling Pt:B.P. Text:250F
Vapor Pres:C.3MMHG
Spec Gravity:0.88
pH:6.0
Solubility in Water:NEGLIGIBLE
Appearance and Odor:LIQUID,SLIGHT REDDISH COLOR,PLEASANT ODOR
Percent Volatiles by Volume:60

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:HEAT,SPARKS,OPEN FLAME.
Hazardous Decomposition Products:THERMAL DECOMP IN THE PRESENCE OF AIR
    MAY YIELD CARBON MONOXIDE &/OR CARBON DIOXIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:BURY SATURATED ABSORBENT IN APPROVED LAND FILL.
    DISPOSE OF AS ANY COMBUSTIBLE FUEL IN ACCORDANCE W/ LOCAL, STATE &
    FED REGS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.